FileFixer certified for MicroStation
V8 XM Edition.
 |
| Red hot
and ready to repair! FileFixer for V8 has
been put through two years worth of testing to ensure
it is ready for the much-anticipated V8 XM Edition. |
CLEARWATER, FLORIDA, USA
Axiom, the worlds most experienced developer
of time-saving MicroStation solutions, announces the release
of FileFixer version 8.7b for MicroStation V8 XM Edition.
FileFixer, Axioms solution for MicroStation design
file corruption, is ready for clients as they move to XM.
FileFixer version 8.7b for
MicroStation V8 XM Edition certification began in 2005 with
early XM betas. Five years worth of carefully collected
and catalogued client files were thoroughly tested to identify
differences in behavior between MicroStation V8 version 8.5
(V8 2004) and 8.9.2.52 (V8 XM). FileFixer for V8 was
enhanced to accommodate key differences. Clients using MicroStation
V8 2004 will also benefit from the FileFixer for V8 version
8.7b enhancements.
When a V8 files level table
is damaged or missing, graphical elements become stranded
on levels which arent defined. In such cases MicroStation
V8s Element Information command displays a blank level
name for the element a blank level name is a symptom
of level table corruption.
When such stranded graphical
elements are modified (moved, scaled, changed symbology, etc.)
MicroStation always moves the element to the Default
level without warning and without choice. One FENCE
MOVE command could completely destroy the level structure
of a design all graphical elements ending up on the
Default level.
FileFixer for V8 offers a
superior solution and keeps the user in control. When a files
level definitions are damaged or missing, FileFixer for
V8 moves each stranded element to a new level, but retains
the original level relationships for all elements. Elements
which previously occupied a particular level are reunited
with all other elements which also occupied that level. New
level names are auto-generated and can be used as is or can
easily be edited in MicroStations Level Manager dialog
to restore their original labels.
FileFixer for V8 version
8.7b now has the ability to create a missing level table (to
which repaired levels can be added). Previously, there were
cases of design file corruption where it was necessary to
manually import a healthy level table by opening the Level
Manager dialog, selecting File|Import, browsing for the correct
level table and hitting <OK> prior to FileFixer repair
processing.
Call now!
For more information on FileFixer
contact an Axiom MicroStation Consultant today! Call 727-442-7774
extension 9578 or e-mail 9578@AxiomInt.com.
« Back
|